Kaytus NF5280M6/LM6
The IEIT Systems NF5280M6/LM6 is a flagship general-purpose 2-socket rack server configured with the 3rd Gen Intel®Xeon® Scalable processors. It maintains the high quality and reliability of IEIT Systems ser\ers and provides flexible air-cooling and liquid-cooling conf1g-uration options (NF5280M6: air-cooling configuration; NF5280LM6: liquid-cooling configuration). With high computing performance, perfect ecological compatibility, and flexible configurations, the NF5280M6/LM6 can meet the application configuration require-ments of various industries. The processor of the liquid-cooling configuration is the first to support cold-plated heat dissipation, helping customers build an energy-saving, carbon-reduction, low-PUE and green data center.
Supports 2 Intel®Xeo11®Scalable processors (Ice Lake) with up to 270W A single CPU supports up to 40 cores witl1 a max Turbo frequency of up to 3.6GHz and up to 3 UPI links at 1l .2GT/s.
Supports up to 32 DDR4 ECC DIMMs (max. 4TB, 3,200MT/s, RDIMMs) to deliver superior speed and high
Supports DCPMMs with a capacity of up to 512GB a11d a bandwidth of 3,200MHz, ensu1-ing memory data integrity in case of a power outage without compromising the memory capacity and bandwidth.
Supports up to 20 5-inch drives or 45 2.5-i11ch drives
Supports up to 32 NVMe SSDs
Supports optional OCP 0 module with multiple network port options (10/25/40/100/200Gbps), delivering a more flexible network architecture to applications.
Supports up to 13 standard PCle expansion cards,Supports optional 1 internal OCP 0 and 1 raid mezz, further enhanc ing 1/0 performance.
Supports optional rear M.2 SSD or RSSD modules for diverse storage demands.
The server allows tool-less maint The enhanced and optimized structural parts enable quick removal/installation, reducing O&M time.
KAYTUS’s unique intelligent control technology combined with the cutting-edge air-cooling technology creates an optimum working environment to ensure the stable operati
With the latest BMC, the UIDLED on the front panel enables the engineers to identify the failed system, and the BMCWeb GUI and LEDs for fault diagnosis can help the engineers to quickly locate components that have failed (or are about to fail), simplifying maintenance, speeding up troubleshooting, and enhancing system availabilit
The BMC can monitor system parameters and send alerts in advance, enabling the engineers to take appropriate measures and ensuring the stable running of the server.
Supports leakage detection to locate the leaked nodes and automatically power off the server, effectively reducing risks.
Supports the warmed water cooling, with a liquid-cooling efficiency of up to 80%.
The efficient cooling capability allows for a reduced number of cooling equipment deployed in data centers. significantly reducing cooling cost
Noise is reduced by about 20 dB compared to air cooling systems as the refrigerant cools the CPU and thereby reduces fan sp
Item | Description | |
Form Factor | 2U rack server | |
Heat Dissipation | NF5280M6 air cooling | NF5280M6 air cooling |
Processor | Two 3rd Gen Intel Xeon Scalable processors per node with up to 270W TDP | |
Chipset | Intel C621A chipset | |
Memory | Up to 32 DIMMs 8 memory channels per processor; upt o 2 DPC; up to 3,200 MT/s RDIMMs and BPS DIMMs; memory protectiontechnologies; ECC, memory mirroring, and memory rank sparing | |
Storage Drive | Front: – 24 x 2,5 inch hot-swap SATA/SAS/NVMe drive – 25 x 2,5 inch hot-swap SATA/SAS drive – 12 x 2,5-/3,5 inch hot-swap SATA/SAS/NVMe drive | Front: – 24 x 2,5 inch hot-swap SATA/SAS/NVMe drive – 12 x 2,5-/3,5 inch hot-swap SATA/SAS/NVMe drive |
| Rear: – 4 x 2,5 inch hot-swap SATA/SAS/NVMe SSD – 4 x 3,5 inch hot-swap SATA/SAS/NVMe SSD – 10 x 2,5 inch hot-swap SATA/SAS drive – 2 x SATA M.2 SSD or 2 x short RSSD (optional) | Rear: – 4 x 2,5 inch hot-swap SATA/SAS/NVMe SSD – 2 x SATA M.2 SSD or 2 x short RSSD (optional) |
| Internal: – 4 x 3,5 inch SATA/SAS drives – 10 x 2,5 inch SATA/SAS drives – Up to 2 TF cards BIOS and BMC (optional) | N/A |
Storage Controller | Raid/SAS controller Onboard PCH that supports 14 SATA connectors Onboard Intel NVMe controller and optional NVMe RAID key | |
Network Port | 1 optional OCP 3.0 module(10/25/40/100/200 Gbps) 2 onboard 10 GbE network ports with a speed of 10 Gbps Standart 1/10/25/40/100/200 Gbps NICs | |
I/O Expansion Slot | Standart config: support up to 11 standart PCIe slots Front I/O config: support up to 13 standart PCIe slots Up to 4 dual-slot GPUs or 8 single-slot GPUs/graphics ards 1 OCP 3.0 x16 NIC; 1 Mezz RAID card | Up to 5 standard PCIe slots Up to 4 dual-slot GPUs 1 OCP 3.0 x16 NIC |
Fan | 2x rear USB 3.0 port + 1x front USB 3.0 port + 1x front USB 2.0 port; 1x front VGA port; 1x rear VGA port | |
Port | 4 hot-swap fans with N=1 redudancy |
|
Power Supply | 550W/800W/1,300W/1,600W/2,000W CPRS standard PSUs wih 1+1 redudancy | |
System Management | Integrated with 1 independent 1,000 Mbps network port, dedicated to IPMI remote management | |
Operating System | Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, etc. |
|
Dimensions (W x H x D) | With Mounting ears: 478,8mm x 87mm x 811,7mm (18,85in x 3,43in x 31,96in) Without mounting ears: 435mm x 87mm x 780mm (17,13in x 3,43in x 30,71in) | |
Weight | Full configuration: < 37.5kg (82.67lbs) (For details please refer to the white paper) | |
Operating Temperature | 5°C to 45°C (47 °F to 113°F) (For details, please refer to the White Paper) |